Projet

Général

Profil

EdgeOS » Historique » Version 14

« Précédent - Version 14/31 (diff) - Suivant » - Version actuelle
Christian Frabel, 04/01/2023 15:08


EdgeOS

ES-48-Lite EdgeOS 1.7.3

Documentation

https://dl.ubnt.com/guides/edgemax/EdgeOS_UG.pdf
https://dl.ubnt.com/guides/edgemax/EdgeSwitch_CLI_Command_Reference_UG.pdf

Commandes

(UBNT EdgeSwitch) #show mac-addr-table 

VLAN ID  MAC Address         Interface              IfIndex  Status
-------  ------------------  ---------------------  -------  ------------
1        00:01:E8:8B:4F:CF   0/49                   49       Learned
1        00:08:7C:3C:29:03   0/49                   49       Learned
128      9C:B6:54:06:7E:56   0/5                    5        Learned
...
show interfaces status all
Port       Name                          State   Mode        Status      Type                Status
---------  ----------------------------  ------  ----------  ----------  ------------------  ------------
0/1                                      Down    Auto                    Unknown             Inactive
0/2                                      Down    Auto                    Unknown             Inactive
0/3                                      Up      Auto        100 Full    Unknown             Active
...

(UBNT EdgeSwitch) #show interfaces switchport

Port: 0/1
VLAN Membership Mode: General
Access Mode VLAN: 1 (default)
General Mode PVID: 3131
General Mode Ingress Filtering: Disabled
General Mode Acceptable Frame Type: Admit all
General Mode Dynamically Added VLANs:
General Mode Untagged VLANs: 3131
General Mode Tagged VLANs: 3199
General Mode Forbidden VLANs: 1,20,128,376,3132,3166,3175
Trunking Mode Native VLAN: 1 (default)
Trunking Mode Native VLAN tagging: Disable
Trunking Mode VLANs Enabled: All
Protected Port: False

Port: 0/2
...
(UBNT EdgeSwitch) #show fiber-ports optics-info all

                         Link Link                                 Nominal
                       Length Length                                   Bit
                         50um 62.5um                                  Rate
Port     Vendor Name      [m] [m]  Serial Number    Part Number     [Mbps] Rev  Compliance
-------- ---------------- --- ---- ---------------- ---------------- ----- ---- ----------------
0/49     OEM              0   0    SG35E40803862    SFP+10GSMD3120LC 10300 A    10GBase-LR
0/50     OPTIC            0   0    STC03051500015   OPTICSFP+10GCP3M 10300 A0   DAC

(UBNT EdgeSwitch) #show fiber-ports optics all     

                                    Output    Input
Port      Temp  Voltage  Current     Power    Power   TX     LOS
           [C]   [Volt]     [mA]     [dBm]    [dBm]   Fault
--------  ----  -------  -------   -------  -------   -----  ---
0/49      45.2    3.332     31.5    -3.079   -3.223   No     No
0/50       N/A      N/A      N/A       N/A      N/A   N/A    N/A

 Temp - Internally measured transceiver temperatures.
 Voltage - Internally measured supply voltage.
 Current - Measured TX bias current.
 Output Power - Measured optical output power relative to 1mW.
 Input Power - Measured optical power received relative to 1mW.
 TX Fault - Transmitter fault.
 LOS - Loss of signal.

Allumer un port et remplir sa description

(UBNT EdgeSwitch) #conf
(UBNT EdgeSwitch) (Config)#interface 0/33

(UBNT EdgeSwitch) (Interface 0/33)#no shutdown

(UBNT EdgeSwitch) (Interface 0/33)#description gentilserveur

(UBNT EdgeSwitch) (Interface 0/33)#exit

(UBNT EdgeSwitch) #write memory 
This operation may take a few minutes.
Management interfaces will not be available during this time.
Are you sure you want to save? (y/n) y

Config file 'startup-config' created successfully .

Configuration Saved!

(UBNT EdgeSwitch) #write memory         

This operation may take a few minutes.
Management interfaces will not be available during this time.

Are you sure you want to save? (y/n) y

Config file 'startup-config' created successfully .

Configuration Saved!
(UBNT EdgeSwitch) #conf

(UBNT EdgeSwitch) (Config)#interface 0/35

(UBNT EdgeSwitch) (Interface 0/35)#shut

(UBNT EdgeSwitch) (Interface 0/35)#do write memory

This operation may take a few minutes.
Management interfaces will not be available during this time.

Are you sure you want to save? (y/n) y

Config file 'startup-config' created successfully .

Configuration Saved!

(UBNT EdgeSwitch) (Interface 0/35)#

(UBNT EdgeSwitch) (Config)#interface 0/12-0/15

(UBNT EdgeSwitch) (Interface 0/12-0/15)#shut
(s58) #copy nvram:startup-config tftp://192.168.3.19/s58

Mode........................................... TFTP  
Set Server IP.................................. 192.168.3.19
Path........................................... ./
Filename....................................... s58
Data Type...................................... Text Configuration

Management access will be blocked for the duration of the transfer
Are you sure you want to start? (y/n) y

File transfer operation completed successfully.

(s58) #

Exemple

À titre d'exemple, activons le port 1 du switch s54 localisé à Picto afin d'y connecter un dispositif.
On peut se connecter au switch de diverses façons, cependant à distance, on peut se connecter d'abord sur nagios.tetaneutral.net et, de là, atteindre s54

@
ssh -lroot -p2222 nagios.tetaneutral.net
@