NXOS » Historique » Version 11
« Précédent -
Version 11/38
(diff) -
Suivant » -
Version actuelle
Laurent GUERBY, 15/02/2018 17:14
NXOS¶
Cisco Nexus 3064X
version 7.0(3)I4
Voir aussi https://www.grenode.net/Documentation_technique/Machines/kraken/
Interface de management out-of-band¶
- n3064a Adresse: 192.168.129.46
interface mgmt0 vrf member management ip address 192.168.129.46/24
Commandes¶
Sauvegarde config¶
nexus# copy run start
Copie via scp
nexus# copy run scp://matthieu@192.168.129.1/
Config interface¶
nexus# conf t nexus(config)# interface ethernet 1/3 nexus(config-if)# switchport mode trunk nexus(config-if)# exit nexus(config)# exit nexus#
pour un vlan non taggé
nexus(config-if)# switchport access vlan 3131
Etat des interfaces¶
nexus# sh int status nexus# sh int transceiver nexus# sh int ethernet 1/1
Boot¶
nexus# conf t nexus(config)# boot nxos bootflash:/nxos.7.0.3.I4.7.bin nexus(config)# boot order bootflash nexus(config)# exit nexus#
Misc¶
service unsupported-transceiver no password strength-check # TODO verifier conf t int eth1/4 switchport trunk allowed vlan xxx switchport trunk native vlan nnn
Infos¶
nexus# sh version Cisco Nexus Operating System (NX-OS) Software TAC support: http://www.cisco.com/tac Copyright (C) 2002-2017, Cisco and/or its affiliates. All rights reserved. The copyrights to certain works contained in this software are owned by other third parties and used and distributed under their own licenses, such as open source. This software is provided "as is," and unless otherwise stated, there is no warranty, express or implied, including but not limited to warranties of merchantability and fitness for a particular purpose. Certain components of this software are licensed under the GNU General Public License (GPL) version 2.0 or GNU General Public License (GPL) version 3.0 or the GNU Lesser General Public License (LGPL) Version 2.1 or Lesser General Public License (LGPL) Version 2.0. A copy of each such license is available at http://www.opensource.org/licenses/gpl-2.0.php and http://opensource.org/licenses/gpl-3.0.html and http://www.opensource.org/licenses/lgpl-2.1.php and http://www.gnu.org/licenses/old-licenses/library.txt. Software BIOS: version 4.0.0 NXOS: version 7.0(3)I4(7) BIOS compile time: 12/05/2016 NXOS image file is: bootflash:///nxos.7.0.3.I4.7.bin NXOS compile time: 6/28/2017 14:00:00 [06/28/2017 21:53:29] Hardware cisco Nexus3000 C3064PQ Chassis Intel(R) Celeron(R) CPU P4505 @ 1.87GHz with 3903284 kB of memory. Processor Board ID FOC17342TSZ Device name: nexus bootflash: 1638000 kB usb1: 0 kB (expansion flash) Kernel uptime is 0 day(s), 2 hour(s), 10 minute(s), 12 second(s) Last reset at 335975 usecs after Wed Feb 14 15:25:27 2018 Reason: Reset Requested by CLI command reload System version: 7.0(3)I4(7) Service: plugin Core Plugin, Ethernet Plugin Active Package(s): nexus# sh inventory NAME: "Chassis", DESCR: "Nexus3000 C3064PQ Chassis" PID: N3K-C3064PQ-10GX , VID: V01 , SN: FOC1734R15F NAME: "Slot 1", DESCR: "48x10GE + 4x40G Supervisor" PID: N3K-C3064PQ-10GX , VID: V01 , SN: FOC17342TSZ NAME: "Power Supply 1", DESCR: "Nexus3000 C3064PQ Chassis Power Supply" PID: N2200-PAC-400W , VID: V04 , SN: DTN1733P0VH NAME: "Power Supply 2", DESCR: "Nexus3000 C3064PQ Chassis Power Supply" PID: N2200-PAC-400W , VID: V04 , SN: DTN1733P0UK NAME: "Fan 1", DESCR: "Nexus3000 C3064PQ Chassis Fan Module" PID: N3K-C3064-FAN-F , VID: V00 , SN: N/A nexus# sh license license_FOC1734R15F_12_1.lic: SERVER this_host ANY VENDOR cisco FEATURE LAN_BASE_SERVICES_PKG cisco 1.0 permanent uncounted \ VENDOR_STRING=<LIC_SOURCE>NEXUS_PRODUCTION</LIC_SOURCE><SKU>N3K-BAS1K9</SKU> \ HOSTID=VDH=FOC1734R15F \ NOTICE=<LicFileID>20131030222602000</LicFileID><LicLineID>1</LicLineID><PAK>N3K-C3064PQ-10GXFOC1734R15F</PAK> \ SIGN=BBF8EBE2F7B6 FEATURE LAN_ENTERPRISE_SERVICES_PKG cisco 1.0 permanent uncounted \ VENDOR_STRING=<LIC_SOURCE>NEXUS_PRODUCTION</LIC_SOURCE><SKU>N3K-LAN1K9</SKU> \ HOSTID=VDH=FOC1734R15F \ NOTICE=<LicFileID>20131030222602000</LicFileID><LicLineID>2</LicLineID><PAK>N3K-C3064PQ-10GXFOC1734R15F</PAK> \ SIGN=FF75EB18A86E
Consommation¶
77 Watt, cos phi 0.92, pas de pic pendant le boot